Dry type electrical transformers manufacturer today

High quality core slitting machine supplier: Poor power quality can severely impact the performance of transformer equipment, leading to a variety of negative outcomes. These consequences not only affect the operational efficiency of the equipment but also pose significant economic concerns. One of the primary damages caused by poor PQ is the deterioration of the transformer’s health. Poor PQ, characterized by factors like voltage sags, swells, harmonics, and transients, can cause excessive heating in transformers. This undue heat can degrade the insulation material used in transformers, subsequently reducing their lifespan and potentially leading to catastrophic failures. Therefore, poor power quality can lead to considerable damage to transformer equipment, resulting in economic losses, reduced energy efficiency, and decreased productivity. Therefore, maintaining high power quality is crucial for the optimal performance of transformer equipment and overall operational efficiency. Discover additional info at https://www.canwindg.com/products-20763.

Canwin is a professional ctl line manufacturers & suppliers china, we have been specialized in ctl machines for over 20 years.This cut to length production line adopts advanced control system to ensure the accurate and stable operation of the cut to length production line. Embedded operating terminal can complete parameter setting quickly and conveniently. After the coil material of silicon steel sheet is punched and cut into certain shape and size by this cut to length production line, the classification and finishing work is completed at the end of the production line, and it is automatically stacked into 20 columns and used for the core assembly.

The transformer coils are referred to as the primary and secondary windings. When applying AC current to the primary winding of the transformer, the transformer coil creates a pulsing magnetic field. The core of the transformer works to direct the path of the magnetic field between the primary and secondary coils to prevent wasted energy.The machine is a very powerful and versatile machine which can wind a wide range of HV coils for distribution transformers using round and rectangular wires. It is fully automatic with paper strip winding.Winding material lnsulated with an epoxy resin -environmentally friendly.

Rising temperature: The capacity of the transformer will decrease as the temperature rises. Therefore, it is necessary to consider the appropriate heat dissipation method and heat dissipation area when designing the transformer to ensure that the temperature rise of the transformer does not exceed the allowable range. Connection method: Different transformer connection methods, such as star, delta, etc., will also affect the capacity of the transformer. For the star connection, the capacity of the transformer can be increased by about 3 times; for the delta connection, the capacity of the transformer is relatively small. Insulation level: The insulation level of the transformer determines the insulation capability and safety performance of the transformer, and also affects the capacity of the transformer. To sum up, the capacity of the transformer is related to factors such as input voltage and output voltage, load nature, temperature rise, connection method and insulation level. When selecting a transformer, it is necessary to comprehensively consider various factors according to the actual situation to ensure the normal operation and stability of the transformer.

Epoxy resin is non – combustible, flame retardant, self – extinguishing solid insulation material, safe and clean. It is also a solid insulation material with proven insulation and heat dissipation technology for more than 40 years.Epoxy resin products can be used for dry type transformer, for insulation parts, for instrument transformer, for electrical composite parts and for room temperature curing. Epoxy resin dry transformer uses epoxy resin as insulation material. The high and low voltage windings are made of copper tape (foil), industrial epoxy resin is poured in vacuum and cured, forming a high strength FRP body structure. Insulation grade F, H. Epoxy resin dry transformer has the characteristics of good electrical performance, strong resistance to lightning impact, strong resistance to short circuit, small size and light weight. Temperature display controller can be installed to display and control the operating temperature of the transformer winding to ensure the normal service life of the transformer.

Independently developed a series of high -speed cut to length line which up to 128 pcs/mins, which increased the cutting speed 2-3 times Independently developed the bridge automatic cutting and automatic lamination cut to length line, which can realize 20 large transformer core column level for automatic lamination, this project has won the record and nomination of Guangdong major research and development projects; Participated in the application and filing of the major science and technology special project of intelligent robot and equipment manufacturing”in the research and development plan of key fields in Guangdong province in 2018-2019. The company has been constantly extending the innovation chain around the guiding ideology of industrial chain deploy innovation chain.

As a result of mutual inductance, a transformer produces a transformed voltage or current when the magnetic flux produced by one winding (primary winding) links with another winding (secondary winding). There is a magnetic coupling between these two windings, and they are electrically isolated. In addition, magnetic reluctance is also known as opposition to magnetic flux flow. If, for example, the magnetic flux produced by a primary winding passes through air or any nonferrous material in order to reach a secondary winding in a transformer, it would result in a reduction in magnetic flux. Due to the high reluctance of air or nonferrous materials, it will reduce magnetic flux. Discover even more info on https://www.canwindg.com/

As a professional energy storage system manufacturer, Canwin specialized in battery energy storage system and containerized energy storage system manufacturing. An energy storage system, often abbreviated as ESS, is a device or group of devices assembled together, capable of storing energy in order to supply electrical energy at a later time. In the energy storage systems, the lithium energy storage battery only interacts with the energy storage converter at high voltage, and the converter takes power from the AC grid to charge the battery pack. Or the battery pack supplies power to the converter, and the electric energy is converted into AC by the converter and sent to the AC power grid.

Dry-type transformers are widely used in local lighting, high-rise buildings, airports, dock CNC machinery and equipment, etc. Simply put, dry-type transformers refer to transformers whose iron cores and windings are not impregnated with insulating oil. The relevant technical parameters of dry-type transformers include: Rated capacity (kVA): The capacity that can be delivered during continuous operation at rated voltage and rated current. Rated voltage (kV): The working voltage that a transformer can withstand during long-term operation.

Why should the iron core of the transformer be grounded? Transformer core grounding is for safety and electromagnetic compatibility considerations. On the one hand, grounding the transformer core prevents contact voltages caused by ground faults, which can pose a shock hazard to humans. Because when a ground fault occurs on one side of the transformer, the iron core on the other side may have a voltage in contact with the earth. If it is not grounded, this voltage cannot be released. On the other hand, grounding the transformer core can also reduce electromagnetic radiation interference, especially for radio equipment and communication systems. This is because the current will generate a magnetic field in the iron core. If the iron core is not grounded, this magnetic field may leak into the surrounding environment and interfere with the normal operation of other equipment. In conclusion, grounding the transformer core is a protective measure against shock hazards and electromagnetic interference.

Oil immersed transformers are the most commonly used equipment mainly because of their simple structure and reliable operation. It has faster heat dissipation, uniform conduction, and better insulation performance than the dry-type transformer.Oil transformers are used in power distribution or electrical substations. Their transformer core and coils are immersed in oil, which cools and insulates. Oil circulates through ducts in the coil and around the coil and core assembly, moved by convection.